Foam Column Density

Estimate foam height, hydrostatic pressure, and pumpability for the gas-liquid mixture above the pump using the Foam Column Density calculator.

Cette page n'est pas encore traduite. Version anglaise affichée.Voir l’original

The Foam Column Density calculator estimates gas-liquid mixture properties in the foam column above the pump: foam height, hydrostatic pressure, fluid gradients, and whether conditions look pumpable.

Open the calculator

  • Calculators hub: open Calculators in the main navigation, then choose Foam Column Density.
  • From a well: open the well → CalculatorsFoam Column Density. Some depth and fluid fields prefill from the well; foam geometry and rates usually need manual entry.

Results update live as you change inputs. There is no Calculate, Reset, or Export button, and nothing is saved back to the well.

Inputs

Wellbore Depth / Geometry

FieldDescription
Pump/Separator TVDTrue vertical depth of the pump or gas separator
TVD of Foam Column TopDepth where the foam / gas-cut column starts
Equivalent Gas free Liquid Above the PumpHeight of liquid you would have if all entrained gas were removed from the foam

Fluid Properties

FieldDescription
Oil DensityOil API gravity
Water Specific GravityProduced water specific gravity relative to pure water

Flow Rates

FieldDescription
Oil RateDaily oil production
Water RateDaily water production

Units follow your Preferences. Invalid inputs clear the outputs until you fix them.

Outputs

Foam Column Pressure / Gradient

OutputDescription
Foam above the pumpPump/Separator TVD minus foam column top
Hydrostatic Pressure of Foam ColumnPressure from the average foam gradient across the foam height
Average gradient of foam columnMean gradient of the foam column
Pressure Gradient of Foam at the PumpGradient at pump depth

Fluid Property Gradients

OutputDescription
Gas Free Fluid Specific GravityOil and water blend by rate cut, with gas removed
Gas Free Fluid GradientGradient of that gas-free fluid
Minimum Pumpable Fluid GradientGas-free gradient × 0.6 (60% liquid assumption)

Current Conditions

OutputDescription
Current Fluid GradientSame as the pressure gradient at the pump
Percent of Gas Free Fluid Gradient (%)Current gradient as a percent of the gas-free gradient

Foam Column Density Gauge

A % Liquid gauge from 0 to 100 with a threshold at 60%:

  • Above 60%Pumpable
  • At or below 60%Not Pumpable

That 60% rule is fixed in the calculator; you cannot change the threshold.

Use Cases

  • Check whether the foam column above the pump still looks pumpable
  • Estimate foam hydrostatic pressure for well control context
  • Compare current fluid gradient to the gas-free baseline